Hernia Research - Hiatal, Inguinal, Umbilical, Abdominal, Treatment

Hernia Research Today is a free monthly online journal that collates and summarizes the latest research about Hernia, including details on hiatal, inguinal, umbilical, abdominal, treatment.


Hernia Research Today

Home

View Latest Issue

Information About Hernia

Books on Hernia

Advertising in Research Today

View Other Research Today Publications



Experimental results of mesh fixation by a manual manipulator in a laparoscopic inguinal hernia repair model.

Inaki N, Waseda M, Schurr MO, Braun M, Buess GF

Section for Minimally Invasive Surgery, Department of General, Visceral, and Transplantation Surgery, University Hospital Tubingen, Tuebingen, Germany. n.inaki@viola.ocn.ne.jp

BACKGROUND: Laparoscopic mesh fixation using a stapler can lead to complications such as nerve injury and bowel injury. However, mesh fixation by suturing with conventional laparoscopic instruments (CLI) is difficult because of limited degrees of freedom. A manual manipulator--Radius Surgical System (Radius)--whose tip can deflect and rotate, gives the surgeon two additional degrees of freedom. The aim of this study is to evaluate the introduction of Radius to mesh fixation in laparoscopic inguinal hernia repair. METHODS: A model for inguinal hernia repair was prepared using animal organs in a trainer. Mesh fixation was performed using Radius, stapler, and CLI. Tensile strength during extraction of mesh toward the vertical direction, and execution time, were measured. RESULTS: The mean number of fixation points of Radius, stapler, and CLI was 9.3 +/- 1.5, 8.5 +/- 1.4, and 9.0 +/- 1.0, respectively. The mean tensile strength of fixation of mesh of Radius, stapler, and CLI was 140.7 +/- 48.9, 73.1 +/- 23.4, and 53.6 +/- 31.5 (N), respectively. The mean tensile strength per one fixation point by Radius, stapler, and CLI was 16.5 +/- 5.3, 8.7 +/- 2.8, and 6.3 +/- 3.6 (N), respectively. The mean execution time of Radius, stapler, and CLI was 479 +/- 108, 54 +/- 31, and 431 +/- 77 (sec), respectively. CONCLUSIONS: The mesh fixation by Radius was stronger than that by staples and CLI. Two additional degrees of freedom were useful in difficult angles. The introduction of Radius is feasible and facilitates the fixation of mesh with sutures in laparoscopic inguinal hernia repair.

Published 12 January 2007 in Surg Endosc, 21(2): 197-201.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Hernia Research Today. All Rights Reserved.



Hernia Research Today Archive:

Volume 1 (2004)
  Issue 1 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Hernia Books

The Official Patient's Sourcebook on Hiatal Hernia: A Revised and Updated Directory for the Internet Age

The Official Patient's Sourcebook on Hiatal Hernia: A Revised and Updated Directory for the Internet Age